MRC-2013-Catalog - page 659

659
VISCOSITY
V
VIS-S3
Direct readout of all measurement parameters on an illuminated Liquid
Crystal Display
Data on screen:
Speed selected: RPM
Spindle
selected: S.P.
Viscosity reading: cP (mPa-s)
Percentage of full scale: %
Sample temperature: °C
Temperature measurement by PT100 probe
Viscosity reading: dynamic viscosity (cP or mPa-s)
The viscometer and the
PT100 can be calibrated by the user
Auto range function to determine
the maximum viscosity with each spindle/speed combination
It can work
with a micro printer
Ultra-sensitive front keyboard that allows easy input of
all parameters
"ERROR" message in the screen with sound alarm when the
viscosity of the test material exceeds the full scale of the selected
combination (SP/rpm.)
Sound alarm if the equipment is working at under
20% of selected full scale
The viscometer is equipped with many pre-sets
speeds, from 0.3 to 100 rpm
Safety protection against sudden rises in the
power supply
English language options
Direct reading in cP (mPa-s).
VIS-8, Digital Basic Rotary Viscometer
Accuracy
± 1% of the full scale
Resolution
Using LVA (Low Viscosity Adapter): 0.01, When viscosity is
lower than 10,000 cP:1, When viscosity is equal or higher
than 10,000 cP:1
Repeatability
0.5%
Temperature Range
from 0.0
o
C to + 100.0
o
C
Resolution
0.1
o
C
Accuracy
±0.1
o
C
Type of Probe
PT 100
Outputs
RS232, Micro Printer
Power
All Models are Supplied with 85/265 VAC
Net Weight
4 kg
Accuracy
± 1% of the full scale
Resolution
Using LVA (Low Viscosity Adapter): 0.01, When viscosity is lower
than 10,000 cP:1, When viscosity is equal or higher than 10,000
cP:1
Repeatability
0.5%
Temperature Range
from 0.0
o
C to + 100.0
o
C
Resolution
0.1
o
C
Accuracy
±0.1
o
C
Type of Probe
PT 100
Outputs
Computer interface RS232, Micro Printer
Power
All Models are Supplied with 85/265 VAC
Net Weight
4 kg
Model
Measuring Range
Fixed Speeds in R.P.M
VIS-8
10-2,000,000 Cp
0.3,0.6,1.5,3,6,12,30,60
Model
Measuring Range
Fixed Speeds in R.P.M
VIS-S1
10-600,000 cP
1-60(nonpolar shift)
VIS-S2
10-6,000,000 cP
0.1-99.9
VIS-S3
10-80,000,000 cP
0.1-99.9
VIS-AI
10-1,000,000 cP
0.1-200.0
VIS-S1/S2/S3/AI, Digital Rotary Viscometer, Without Limits
Direct readout of all measurement parameters on an illuminated Liquid Crystal Display
Data on screen:
Speed
selected: r.p.m.
Spindle selected: S.P.
Viscosity reading: cP (mPa-s)
Percentage of full scale: %
Sample
temperature: °C
Temperature measurement by PT100 probe
Viscosity reading: dynamic viscosity (cP or mPa-s)
The viscometer and the PT100 can be calibrated by the user
Auto range function to determine the maximum
viscosity with each spindle/speed combination
It can work with a micro printer
Ultra-sensitive front keyboard that
allows easy input of all parameters
“ERROR” message in the screen with
sound alarm when the viscosity of the test material exceeds the full scale
Sound alarm if the equipment is working at under 20% of selected full
scale
The viscometer is equipped with many pre-sets speeds, from 0.1 to
100 rpm
Safety protection against sudden rises in the power supply
English language options
Direct reading in cP (mPa-s).
VIS-8
Rotary
1...,649,650,651,652,653,654,655,656,657,658 660,661,662,663,664,665,666,667,668,669,...738