MEGA - GC products 2014A - page 6

Stationary Phase
T
max
*
3S0°C
3S0°C
3S0°C
3S0°C
2S0°C
340°C
2S0°C
3S0°C
3S0°C
Equivalent to
DB-I ,HP-I,AT-I,ZB-I ,
007-1,Rtx-I, BP-I,
SPB-I ,CP Sil 5 CB
DB-5, HP-5,AT-5,ZB-5,
007-5, Rtx-5, BP-5,
SPB-5, CP Sil 8 CB
SE52
SE54
DB-1701, HP-1701 ,AT-1701,
ZB-1701,007-1701 ,Rtx-1701,
BP-I 0,SPB-170I ,CP Sil 19 CB
DB-17, DB-608, HP-17,AT-50,
ZB-50, 007-17, Rtx-17, BPX-50,
SPB-50, CP Sil 24 CB
DB-Wax, HP-Wax, InnoWax
AT-Wax, ZB-Wax, 007-CW,
Rtx-Wax,BP-20, CPWax 52 CB
DB-I ms(UI),HP-1 ms,
ZB-I ms,Rtx-I ms,BPX-I ,
Equity-I, CP Sil 5 CBms
DB-5 ms (UI), HP-5 ms,
AT-5 ms,ZB-5 ms,007-5 ms,
Rtx-5 ms,BPX-5, Equity-5
EPA - USP- Methods
**
EPA504,1,505,551 ,606,
612,8141A/B, etc**
USP GI,G2, G9,G38
EPA506,61 1,604,607,608,
8015,8041,8082,8091, etc**
USP G27, G36, G41
USP G27, G36, G41
EPA513, 5152, 5522, 607,
619,622, 809 I ,8121,etc**
USP: G46
EPA: 604,608,619,8060,8081
USP G3,GI7
EPA602, 603, 619,
8015CUSP467 (OVls), etc **
USP:G14, GIS, G16,etc
EPA504, I ,505,606, etc**
USP GI, G2, G9, G38
EPA513, 528, 552, 61 0,613
1625,8100, 8141
AlB,
etc**
USP G27,G36,G41
Applications
General purpose column,Solvent impurities, PCBs,
simulated distillation,drugs, gases, natural gases,
essential oils,semivolatiles, pesticides,phenols, etc
General purpose column,Solvent impurities, PCBs,
hydrocarbons, essential oils,semivolatiles,
pesticides,etc
General purpose column,Solvent impurities, PCBs,
hydrocarbons, essential oils,semivolatiles,
triglycerides, pesticides, poly-waxes, etc
General purpose column,Solvent impurities, PCBs,
hydrocarbons, essential oils,semivolatiles,
allergens,pesticides,etc
General purpose column,Residual solvents, PCBs,
alcohols, oxygenates, pesticides,etc
Ideal asconfirmation column and GCxGC use,
General purpose column, Phthalate esters,
herbicides, pharmaceuticals, etc
Ideal asconfirmation column and GCxGC use,
General purpose column,FAMEs, flavor compounds,
essential oils,BTEX aromatics, solvents,alcohols, etc
Tune yourWax column polarity' Ask us for more info.
General purpose column for GC-MSuse,
SeeMEGA-I phase,
General purpose column for GC-MS use,
SeeMEGA-5 phase,
All trademarks mentioned in this docu
": the temperature range maychange (
**:
download on our website amore (
basis ofEPAmethods, USP
requirerne
HRO~'-:'I.J'II-=
+61(0}397622034 AustralianDistributors
1.Ji11
Importers
&
Manufacurers
..,,/15
_
ECH
17~I~g'yPty
Ltd
Website NEW:
E-mail:
Tel: 03 9762 2034 ••• in AUSTRALIA
1,2,3,4,5 7,8,9,10,11,12,13,14,15,...16
Powered by FlippingBook