Specifications
Range
H
2
S, SO
2
, NO
2
......................................... 0-100 ppm
CO, NO
x
.............................................. 0 - 1,999 ppm
Alarm (high)
H
2
S, SO
2
, NO
2
......... Audible and visible at 100 ppm
CO, NO
x
................... Audible and visible at 200 ppm
Display ....................................... LCD, 1 ppm increments
Linearity .............................................................. ± 2 ppm
Accuracy ........................................... ± 10 ppm full range
...................
± 5 ppm if used up to 100 ppm maximum
Calibration ......................................... Two point required:
...............................
ZERO adjust with clean air or N
2
;
......
SPAN adjust with ~50% full scale calibration gas
Toxic Gas Monitors/Alarms
Specifications
Case material ............................ High impact polystyrene
Case dimensions ............................... 5.25" x 2.5" x 1.25"
Weight............................................................. 250 grams
Recorder output........................................... Not provided
Temp limits........................................................ 0 to 40°C
Power source.............................. One 9V alkaline battery
Battery life, continous ............. 1500 hours, with no alarm
Low battery indicator............................... LCD ‘B’ Display
Response time ............................... 90% in < 20 seconds
Sensor mounting ...........Internal (optional external cable)
Sensor life ...................................... Warranted: 6 months
Expected: 9 months
Ordering information
All monitors below include a sensor, instruction booklet, screw driver, and span gas flow cup and tubing.
US customers
call toll-free
(877) 737-1887
VICI
®
is a registered trademark of Valco Instruments Co. Inc. and VICI AG.
North America, South America, and Australia/Oceania contact:
Europe, Asia, and Africa contact:
Metronics Inc.
tel: 360 697-9199
fax: 360 697-6682
metronics@vici.com
VICI AG International
For detection of
Model
Spare sensor
Remote cable
Vinyl case
CO
GC-401
GC44-300
GC401-RC GC501-505
H
2
S
GC-701
GC44-700
GC401-RC GC501-505
SO
2
GC-801
GC44-800
GC401-RC GC501-505
NO
x
GC-901
GC44-900
GC401-RC GC501-505
NO
2
GC-952
GC44-500
GC401-RC GC501-505
rev 10/06
PB-022 gcal_monitors
tel: Int + 41 41 925-6200
fax: Int + 41 41 925-6201
info@vici.ch
Website : www.chromtech.net.au E-mail : info@chromtech.net.au TelNo : 03 9762 2034 . . . in AUSTRALIA