Restek-OEM-Parts_780p - page 44

Inlet Liner Packing Materials & Accessories
800-356-1688
5
ReplacementCarboFrit™ Inserts
Description
qty.
cat.#
price
Frits for liner ID
4mm
10-pk.
20295
$43
Frits for liner ID>4mm
10-pk.
20294
$43
CarboFrit™Puller/InserterTool
• Hook end for removingCarboFrit™ inserts.
• Bent end (90°) for insertingCarboFrit™ inserts.
Description
qty.
cat.#
price
CarboFrit
Puller/InserterTool
ea.
21642
$14
DeactivatedFusedSilicaBeads
• Increase sample vaporization surface andminimize splitter discrimination to improve quantitationof
compounds havingdissimilar boilingpoints.
• Trapnon-volatile or inorganic residue toprevent column inlet contamination.
• Deactivated, heat-treated, and tested to ensure complete inertness.
InletLinerRemovalTool
• Easily remove liner from injector—nomore burned fingers.
• Made fromhigh-temperature silicone.
• Won’t chipor crack the liner.
Description
qty.
cat.#
price
Inlet Liner RemovalTool
3-pk.
20181
$27
CarboFrit™ InletLinerPackingMaterial
• Highly inert.
• Extends analytical column lifetime.
• Enhances reproducibilityof split and splitless injection.
• Uniformpore size and consistent packingdensity guarantee consistent flow through the liner.
• Easy to install in any linerwith an ID>3.5mmwhenusingpuller-inserter tool listedbelow.*
*Linerswith IDs less than 3.5mm are difficult to pack.Wewill pack them on a custom basis (minimum neck ID of 2mm required).
Description
suffix
price
each
-209.1
$14
addl. cost
5-pk.
-209.5
$29
addl. cost
25-pk.
-209.25
$79
addl. cost
Nomoreburned
fingers!
a
plus1
story
“Restek sent us some carbonmaterial (CarboFrit
packing) with the suggestion to test it as liner packing. Initially, I didn’t evenwant to
try it because carbon is usually highly retentive and catalytically active. Aswe nevertheless gave it a chance, wewere highly
surprised…it exhibited low retentive power and good inertness.”
excerpt from:
Sample Evaporation inHot GC Injectors
,
Dr. KonradGrob,
TheRestek Advantage
,Winter 1996.
tech
tip
Use of Packingswith Splitless Liners
We recommend using an injection port linerwithwool or CarboFrit
packingwhenmaking splitless injectionswith an autosampler.
If there is no packingmaterial in the liner, the solvent droplets act likewater on a hot iron: they bounce around until vaporized
(Leidenfrost phenomenon). Because autosamplersmake rapid injections, samples can be incompletely vaporized, leading to
non-reproducible peak response and tailing. You can prevent this by usingwool or CarboFrit
packingmaterial in the splitless liner,
to provide a surface for the solvent droplets to “sit” on until the heat from the injector vaporizes them.
Add the corresponding suffixnumber to the liner catalognumber.
Description
Mesh
qty.
cat.#
price
Deactivated Fused Silica Beads
60-80
25 grams
20791
$64
1...,34,35,36,37,38,39,40,41,42,43 45,46,47,48,49,50,51,52,53,54,...780