Restek-OEM-Parts_780p - page 183

DI Liners for Agilent GCs
(For 0.32/0.53mm IDColumns)
Benefits/Uses
ID*/OD&
Length (mm)
cat.#
/price
ea.
cat.#
/price
5-pk.
1mmUniliner
®
**
trace, active samples, samples
<1µL
1.0 ID
6.3OD x 78.5
21052
$69
21053
$274
Siltek
®
1mmUniliner
®
**
trace, active samples, samples
<1µL
1.0 ID
6.3OD x 78.5
21052-214.1
$74
21053-214.5
$294
Uniliner
®
**
trace, active samples, high
recovery & linearity
4.0 ID
6.3OD x 78.5
20335
$60
20336
$237
Siltek
®
Uniliner
®
**
trace, active samples, high
recovery & linearity
4.0 ID
6.3OD x 78.5
20335-214.1
$65
20336-214.5
$257
Cyclo-Uniliner
®
**
trace, dirty, highMW active
samples, high recovery
& linearity
4.0 ID
6.3OD x 78.5
20337
$72
20338
$288
Siltek
®
Cyclo-Uniliner
®
**
trace, dirty, highMW active
samples, high recovery
& linearity
4.0 ID
6.3OD x 78.5
20337-214.1
$77
20338-214.5
$308
Open-topUniliner
®
w/Wool**
trace, dirty, active samples,
high recovery & linearity
4.0 ID
6.3OD x 78.5
20843
$49
20844
$194
Siltek
®
Open-topUniliner
®
w/Wool**
trace, dirty, active samples,
high recovery & linearity
4.0 ID
6.3OD x 78.5
20843-213.1
$68
20844-213.5
$243
DI Liners for Agilent 5890& 6890GCs
(For 0.25/0.32/0.53mm IDColumns)
Benefits/Uses***
ID*/OD&
Length (mm)
Similar to
Agilent part#
ea.
cat.#
/price
5-pk.
25-pk.
DrilledUniliner
®
(hole on top)
trace, active samples, high
recovery & linearity
4.0 ID
6.3OD x 78.5
21054
$64
21055
$253
20998
$1085
Siltek
®
DrilledUniliner
®
(hole on top)
trace, active samples, high
recovery & linearity
4.0 ID
6.3OD x 78.5
21054-214.1
$69
21055-214.5
$273
20998-214.25
$1175
DrilledUniliner
®
(hole on bottom)
trace, active samples, high
recovery & linearity
4.0 ID
6.3OD x 78.5
G1544-80730
20756
$64
20771
$284
DoubleGooseneck DrilledUniliner
®
(hole on top)
trace, active samples, high
recovery & linearity
4.0 ID
6.3OD x 78.5
20508
$64
20509
$253
DoubleGooseneck DrilledUniliner
®
(hole on bottom)
trace, active samples, high
recovery & linearity
4.0 ID
6.3OD x 78.5
G1544-80700
20954
$64
20989
$284
Siltek
®
1mmDrilledUniliner
®
(hole on top)
trace, active samples, high
recovery & linearity
1.0 ID
6.3OD x 78.5
21390-214.1
$74
21391-214.5
$295
*Nominal ID at syringe needle expulsion point.
**TheseUniliner
®
liners are for split/splitless injection ports.
†This liner for usewith 0.25, 0.32, or 0.53mm ID columns.
Siltek®Metal InletLiners forAgilentGCs
• Won’t crack, chipor break like glass liners.
• Inertness equivalent to glass liners.
• Excellent response for pesticides, phenols, andother active compounds.
Liner Type (5.2mm ID x 6.3mmOD x 78.5mm)
5-pk.
25-pk.
Cyclo/SingleGooseneck
20974
$219
20975
$853
SingleGooseneck
21702
$93
21703
$415
Cyclosplitter
®
20726
$141
20729
$560
Split/Splitlessw/Wool
21700
$45
21701
$179
***Hole inDrilledUniliner®makesdirect injection
possiblewithEPC-equipped6890GCs!
C O L U M N I N S T A L L S T H I S E N D
Inlet Liners
800-356-1688
8
tech
tip
DrilledUniliner
®
Use theDrilledUniliner
®
with theholenear thebottom for analysis inwhich compounds of interest couldbeaffectedby a tailing solvent peak. Use theDrilled
Uniliner
®
with theholenear the top for aqueous injections, aswell as for analysis inwhich the compounds of interest eluteaway from the solvent peak.
All liners are shipped
intermediate polarity
(IP) deactivated unless
otherwise requested.
All linersare
100%
deactivated