GC/HPLC Accessories Mini Catalog - page 31

230
GC ACCESSORIES |
INSTRUMENT SUPPLIES
Suppl ies for Agi lent GCs : Tools
Air Diverter
for Agilent GCs
• Divert GC exhaust heat up and away from the lab bench.
• Meets or exceeds original manufacturer’s performance.
• Easy to install—no tools required.
Oven Flapper Assemblies
for Agilent 5890/6890 GCs
• Ensure even and consistent column heating when the
insulation becomes damaged or worn.
• Replacement Insulation Gasket and Hardware Kit includes
the insulation gasket, 2 screws and 2 nuts.
• Meets or exceeds original manufacturer’s performance.
• Insulation is replaceable, using Restek’s Oven Flapper
Assemblies.
*Fits Restek’s Oven Flapper Assembly only.
22996
22995
Screw the tool completely onto the injection
port in a clockwise direction. Unscrew the tool
and inspect the threads, repeat as necessary.
When done, wipe threads with methanol to
remove any debris.
Make your injection port
threads like new!
22076
23018
22065
Description
Similar to
Agilent part # qty.
cat.#
price
Oven Flapper Assembly
for Agilent 5890 GCs
05890-80560 ea.
22994
Oven Flapper Assembly
for Agilent 6890 GCs
G1530-80560 ea.
22995
Replacement Insulation Gasket and
Hardware Kit*
kit
22996
Description
Similar to
Agilent part # qty.
cat.#
price
Air Diverter for Agilent
5890/6890/7890 GCs
19247-60510,
G1530-80650 ea.
22076
Injector Wrench
for Agilent 5890/6890/6850 GCs
• Use to remove the septum nut and
weldments during GC maintenance.
• Use the smaller end to remove the
septum nut.
• Use the larger end to tighten the
split/splitless weldment nut.
• High-quality stainless steel construction.
• Meets original equipment performance.
Description
Similar to
Agilent part # qty.
cat.#
price
Injector Wrench for Agilent
5890/6890/6850 GCs
19251-00100 ea.
22065
Rethreading Tool
for Agilent Split/Splitless Injection Ports
• Repair worn or damaged threads
in injection ports, fittings, etc.
• Built-in guide to prevent
cross-threading.
Worn & damaged threads can allow oxygen into the system—
compromising analytical results and destroying columns.
Description
qty.
cat.#
price
Rethreading Tool for
1
/
4
" compression fittings
(Agilent split/splitless injection ports)
ea.
23018
Looking for a
Simple Solution?
See pages 206-211 for details.
New Sky™ liners, featuring a state-
of-the-art deactivation, give you the
inertness you need for accurate,
reproducible trace level results.
Website :
E-mail :
TelNo : 03 9762 2034 . . . in AUSTRALIA