GC Columns Mini Catalog - page 25

41
GC COLUMNS |
HIGH-PERFORMANCE Rxi COLUMNS
Rxi®-1ms, Rxi®-5ms
free
literature
Rxi®-1ms: The
Ultimate High
Performance Fused
Silica Capillary
Column
Download your free
copy from
lit. cat.# 580075B
CH
3
CH
3
Si
100%
O
Rxi®-1ms Structure
free
literature
Rxi®-5ms Columns
Download your free
copy from
lit. cat.# 580046A
CH
3
CH
3
Si
95%
O
Si
5%
O
Rxi®-5ms Structure
similar
phases
DB-1, DB-1ms, HP-1, HP-1ms, Ultra-1, SPB-1,
Equity-1, VF-1ms, CP-Sil 5 CB Low Bleed/MS
Rxi®-1ms Columns
(fused silica)
(nonpolar phase, Crossbond® 100% dimethyl polysiloxane)
• General purpose columns for drugs of abuse, essential oils, hydrocarbons, pesticides,
PCB congeners (e.g. Aroclor mixes), sulfur compounds, amines, solvent impurities,
simulated distillation, oxygenates, gasoline range organics (GRO), refinery gases.
• Tested and guaranteed for ultra-low bleed—improved signal-to-noise ratio, for
better sensitivity and mass spectral integrity.
• Temperature range: -60 °C to 330/350 °C (bleed tested temperature/maximum
operating temperature).
• Equivalent to USP G2 phase.
similar
phases
DB-5, HP-5, HP-5ms, Ultra-2, SPB-5, Equity-5,
CP-Sil 8
Rxi®-5ms Columns
(fused silica)
(low polarity phase, Crossbond® 5% diphenyl/95% dimethyl polysiloxane)
• General purpose columns for semivolatiles, phenols, amines, residual solvents, drugs
of abuse, pesticides, PCB congeners (e.g. Aroclor mixes), solvent impurities.
• Most inert column on the market.
• Tested and guaranteed for ultra-low bleed—improved signal-to-noise ratio, for
better sensitivity and mass spectral integrity.
• Temperature range: -60 °C to 330/350 °C (bleed tested temperature/maximum
operating temperature).
• Equivalent to USP G27 phase.
ID df
temp. limits
15-Meter
30-Meter
60-Meter
0.25mm 0.25µm -60 to 330/350°C
13320
13323
13326
0.50µm -60 to 330/350°C
13335
13338
13341
1.00µm -60 to 330/350°C
13350
13353
13356
0.32mm 0.25µm -60 to 330/350°C
13321
13324
13327
0.50µm -60 to 330/350°C
13336
13339
13342
1.00µm -60 to 330/350°C
13351
13354
13357
4.00µm -60 to 330/350°C
13396
0.53mm 0.50µm -60 to 330/350°C
13337
13340
1.00µm -60 to 330/350°C
13352
13355
1.50µm -60 to 330/350°C
13367
13370
13373
ID df
temp. limits
10-Meter
12-Meter
20-Meter
25-Meter
50-Meter
0.10mm 0.10µm -60 to 330/350°C 13301
0.18mm 0.18µm -60 to 330/350°C
13302
0.36µm -60 to 330/350°C
13311
0.20mm 0.33µm -60 to 330/350°C
13397
13398
13399
ID df
temp. limits
15-Meter
30-Meter
60-Meter
0.25mm 0.25µm -60 to 330/350°C
13420
13423
13426
0.40µm -60 to 330/350°C
13481
0.50µm -60 to 330/350°C
13435
13438
13441
1.00µm -60 to 330/350°C
13450
13453
13456
0.32mm 0.25µm -60 to 330/350°C
13421
13424
13427
0.50µm -60 to 330/350°C
13436
13439
13442
1.00µm -60 to 330/350°C
13451
13454
13457
0.53mm 0.25µm -60 to 330/350°C
13422
13425
0.50µm -60 to 330/350°C
13437
13440
1.00µm -60 to 330/350°C
13452
13455
1.50µm -60 to 330/350°C
13467
13470
ID df
temp. limits
10-Meter
12-Meter
20-Meter
25-Meter
50-Meter
0.10mm 0.10µm -60 to 330/350°C 13401
0.18mm 0.18µm -60 to 330/350°C
13402
0.30µm -60 to 330/350°C
13409
0.36µm -60 to 330/350°C
13411
0.20mm 0.33µm -60 to 330/350°C
13497
13498
13499
Website :
E-mail :
TelNo : 03 9762 2034 . . . in AUSTRALIA
Mar 2011
1...,15,16,17,18,19,20,21,22,23,24 26,27,28,29,30,31,32,33,34,35,...151