restek-tnx14 - page 407

18
For detailed informationon types
of guard columns, their uses, and
a complete product listing,
requestRestek’s
GuardColumn
Fast Facts
flyer
(lit. cat.#59319)
Intermediate-PolarityDeactivatedGuardColumns
Nominal ID (mm)
NominalOD (mm)
1-Meter
5-Meter
0.15
0.363± 0.012
10101
10042
0.18
0.37± 0.04
10102
10046
0.25
0.37± 0.04
10043
0.28
0.37± 0.04
10003
0.32
0.45± 0.04
10044
0.45
0.69± 0.05
10005
0.53
0.69± 0.05
10045
for
more
info
Innovative Integra-Guard
Columns
Some people swear bypress-fit connectors, andothers swear at them. Formany analysts, the
art of attaching a guard column to an analytical column is amystery. Restek’s chemists have
discovered the solution to thismystery—the easiest,most reliable connection is no connection
at all!Noguard column system ismore permanent thanone continuous lengthof tubing
containingboth theguard column and the analytical column.
Restekoffers awidevarietyof Integra-Guard
capillary columnswith aguaranteed leak-free
connection!Theguard column is tied separately from the analytical column, usinghigh-
temperature string. The transition area between the columns is the point atwhich the guard
column ends and the analytical columnbegins. The entire setup is suspended inour unique
“crush-free” cage,whichprevents the column from coming in contactwith anything that
coulddamage it.
Ordering is simple. Just add theappropriate suffixnumberandprice to theanalytical column’s
catalognumberandprice. For example, a30m, 0.25mm ID, 0.25µmRtx
®
-5MSwitha5m
Integra-Guard
column iscat.#12623-124.
ID (mm)
Length (m)
Suffix#
0.25
5
-124
10
-127
0.28
5
-243
10
-244
Integra-Guard
built-inguard
column
Phases currently available as
Integra-Guard
columns:
Rtx
®
-1
Rtx
®
-1701
Rtx
®
-1MS
Rtx
®
-Volatiles
Rtx
®
-5
Rtx
®
-20
Rtx
®
-5MS
Rtx
®
-35
Rtx
®
-5SilMS Rtx
®
-35MS
XTI
®
-5
Rtx
®
-BAC1&2
Rtx
®
-1301
Stabilwax
®
Rtx
®
-624
ID (mm)
Length (m)
Suffix#
0.32
5
-125
10
-128
0.53
5
-126
10
-129
For analystswhoprefer toattachaguard column to the analytical column
themselves, Restekoffers deactivatedguard columns andPress-Tight
®
connectors.
Press-Tight
®
Connectors
Seals all common sizes (0.18 to0.53mm ID, outside diameters from0.3 to0.75mm) of
fused silica tubing.
Connect guard columns to analytical columns, repair broken columns, or connect column
outlets to transfer lines.
Angledconnectorsaredesigned toapproximate thecurvatureofacapillarycolumnandreduce
strainoncolumn-endconnections.
Made from inert fused silica.
Universal AngledPress-Tight
®
Connectors
:
cat.#20446 (5-pk.); cat.#20447 (25-pk.); cat.#20448 (100-pk.)
Universal Press-Tight
®
Connectors:
cat.#20400 (5-pk.); cat.#20401 (25-pk.); cat.#20402 (100-pk.)
DeactivatedUniversal Press-Tight
®
Connectors
:
cat.#20429 (5-pk.); cat.#20430 (25-pk.); cat.#20431 (100-pk.)
Universal “Y”Press-Tight
®
Connectors
:
cat.#20405 (ea.); cat.#20406 (3-pk.)
Universal Angled“Y”Press-Tight
®
Connectors
:
cat.#20403 (ea.); cat.#20404 (3-pk.)
Website :
E-mail :
TelNo : 03 9762 2034 . . . inAUSTRALIA
1...,397,398,399,400,401,402,403,404,405,406 408,409,410,411,412,413,414,415,416,...417