restek-tnx14 - page 229

63
Ordering Information
| Siltek
-DeactivatedGuardColumns
Siltek
-DeactivatedGuardColumns/Transfer Lines
• Revolutionary deactivation process lowers endrin breakdown to less than 1%.
• Minimize bleed.
• Ideal for chlorinated pesticide analysis.
• Analyze tough samples quickly and accurately.
• Maximum temperature of 380°C.
• Reduces effects of dirty samples on column performance.
• Reduces downtime andmaintenance.
Nominal ID
Nominal OD
5-Meter
0.32mm
0.45 ± 0.04mm
10027
0.53mm
0.69 ± 0.05mm
10028
Low-Volume Injector for Agilent 5890 SeptumPackedPurgePort
• Allows syringe injections onto the column for purge& trap troubleshooting or
calibration.
• Silcosteel
®
treatment eliminates adsorption of active compounds.
• Attaches toGC inlet without cutting injection port lines.
Everything you need for installation is provided, including a
1
/
16
-inch nut, a
1
/
16
-inch ferrule,
a base nut and
1
/
4
-inchVespel
®
/graphite ferrule, a
1
/
16
-inch capillary nut, a 5-pack of low-
bleed plug septa, and a special low-mass septum nut. Order appropriate capillary ferrules
separately—see our catalog.
Description
qty.
cat.#
Low-Volume Injector for Agilent 5890 SeptumPacked Purge Port
kit
21698
Low-Volume Injector for Agilent GCs
• FitsAgilent split/splitless injectors.
• Attaches to theGC inlet without cutting existing injection port lines.
• Allows injections from a syringe onto the column for purge& trap troubleshooting
or calibration.
• Silcosteel
®
treatment eliminates adsorption of active compounds.
Our low-volume injector canbe installed in amatter ofminutes. Remove the septumnut or
splitless weldment and insert the Restek low-volume injector through the split injector.
Tighten the base nut and you’re ready! Includes a
1
/
16
-inch nut, a
1
/
16
-inch ferrule, a base nut
and
1
/
4
-inch Vespel
®
/graphite ferrule, a
1
/
16
-inch capillary nut, a 5-pack of low-bleed plug
septa, and a low-mass septum nut. Order appropriate capillary ferrules separately—see our
catalog.
Description
qty.
cat.#
Low-Volume Injector for Agilent Split/Splitless GC Inlets
kit
21692
Low-Volume Injector for Varian Split/Splitless Inlets
• Attaches to theGC inlet without cutting existing injection port lines.
• Allows injections from a syringe onto the column for purge& trap troubleshooting or
calibration.
• Silcosteel
®
treatment eliminates adsorption of active compounds.
• Order capillary ferrules separately—see our catalog.
Description
qty.
cat.#
Low-Volume Injector for Varian Split/Splitless GC Inlets
kit
21693