Restek ESSENTIALS 2010-2012 - page 91

14
Air Sampling
Also available in stainless steel. Air sampling canisters sold separately.
Siltek Treated
Canister Volume/Sampling Time (min.)
Flow
Grab Sampling Kits
1 L Canister 3 L Canister 6 L Canister (mL/min.) Orifice Size cat.#
60
— — 15
0.0018"
26280
30
— — 20
0.0020"
26281
15
60
— 45
0.0030"
26282
— 30
60
80
0.0040"
26283
5
15
30
150
0.0055"
26284
— — 15
300
0.0080"
26285
— 5
— 390
0.0090"
26286
— — 5
>1,000 0.0130"
26287
• Provideaccurate integrated sampling
without a samplingpump.
• Siltek® treatedcomponentsensureaccurate
samplingof activecomponents.
• Excellent for sampling times from0.5hour
to125hours.
Also available in stainless steel. Air sampling canisters sold separately.
Canister Volume/Sampling Time
Flow Orifice Siltek Treated
400cc 1 Liter 3 Liter
6 Liter 15 Liter (mL/min.)
size
Sampling Kits
8 hour 24 hour 48 hour 125 hour
— 0.5–2 0.0008"
24217
2 hour 4 hour 12 hour 24 hour 60 hour
2–4 0.0012"
24160
1 hour 2 hour 6 hour 12 hour 30 hour
4–8 0.0016"
24161
— 1 hour 4 hour
8 hour 20 hour
8–15 0.0020"
24162
— — 2 hour
3 hour 8 hour
15–30 0.0030"
24163
— — — 1.5 hour 4 hour
30–80 0.0060"
24164
— — — 0.5 hour 1 hour 80–340 0.0090"
22101
• Duplicate samplingwithall sizecanistersusing1or 2 flow
controllers.
• Precisedimensions (9.5"widex3.5"high) provideaccurate
splittingof samplebetween twocanisters.
• One-piecedesignmeans fewer leaks.
• Thickwalled stainless steel tubing is ruggedenough for field
use.
1
/
4
" compressionconnections.
Note: Do not use theDCSM as a handle to pick up 2 canisters!
Stainless Steel
Sulfinert Treated
Description
cat.#
cat.#
Dual Canister SamplingManifold
24998
24999
Assembledsampler includes:
• Stainless steel teewithorifice.
• 11/2" vacuumgauge (-30"Hg to0"Hg).
• 2μm frit filter for insertion into
1
/
4
" compression sample inlet.
1
/
4
"port connector tocanister valve.
Air sampling canisters sold separately.
Thisuniquegrab sampler is specificallydesigned
for soil gas samplingbyallowing theconnectionof
tubingcoming from the soil gas sampleport. The
innovativedesignminimizes connectionsand leaks
andhousesacritical orifice in the tee fitting. It also
incorporatesavacuumgaugeand2μm frit filter.
CanisterPassiveSamplingKits
ForWholeAir SamplingWithout aPump
• Usewith1, 3, or 6Lcanisters, for
qualitativegrabair sampling.
• Varietyof orifice sizes, for fast sampling
from5 to60minutes.
1
/
4
" compression fittingconnectsdirectly to
canister valve inlet.
• Replaceable fritprotectsorificeandvalve from
particulates.
• Sample inletdesignminimizeswater entry into
sampling train.
• Individual replacement componentsavailable.
Siltek Treated
Stainless Steel
Sampling Time
Soil Gas Sampler Kit Soil Gas Sampler Kit
for 6 L Canister
Flow Orifice Size cat.#
cat.#
20min.
210mL/min.
0.0065"
22935
22930
30min.
150mL/min.
0.0055"
22936
22931
1 hr.
80mL/min.
0.0040"
22937
22932
4 hr.
19mL/min.
0.0020"
22938
22933
10 hr.
6mL/min.
0.0014"
22939
22934
DualCanisterSampling
Manifold
StainlessSteel
&Sulfinert®
Treated
SoilGasSampler
StainlessSteel &Sulfinert®Treated
IntegratedSamplingKits
PassiveAirSamplingKits—Integrated
GrabSamplingKits
PassiveAirSamplingKits—Grab
NEW!
NEW!
NEW!
innovativechromatographyproducts
1...,81,82,83,84,85,86,87,88,89,90 92,93,94,95,96,97,98,99,100,101,...173
Powered by FlippingBook