restekadv07 - page 72

Capillary
Nut
$175
22423
kit
EZNo-Vent
Connector Kit for Varian Saturn 2000 SeriesMSs
• 23 •
800-356-1688 •
2005vol. 1
EZNo-Vent™GCColumn-MSConnector
Change Columns inMinutesWithout Venting
byDonna Lidgett, GCAccessories ProductMarketingManager
•Save hours of downtime—100µm transfer line throttles vacuum and preventsMS pump-
down.
•Easy to install andmaintain—no special tools or plumbing required.
•Gold-plated body for inertness.
•Deactivated transfer line keeps analytes focused; high-temperature polyimide ferrules
eliminate leaks at the problematic transfer line fitting.
•Lower cost than other “no-vent” fittings.
•Available for Agilent GCswith 5971/5972 or 5973GC/MS, Varian Saturn 2000 SeriesMSs.
We designed the EZNo-Vent
connector to be
simple and easy to use. A critical orifice in
the EZNo-Vent
connectorminimizes the
amount of oxygen allowed into theMS
source, eliminating the need for purge gas
and enabling you to skip the lengthy vent and
pump-down cycle otherwise requiredwhen
youmake a column change.This can save
nearly a day of downtimewith each column
change.The EZNo-Vent
connector easily
attaches to theMS sourcewithout special
tools or extra plumbing.
Description
qty.
cat.#
price
EZNo-Vent
Connector Kit for Agilent 5971/5972 and 5973GC/MS
kit
21323
$175
Replacement ferrules for connecting capillary column to EZNo-Vent
:
0.4mm ID
2-pk.
21015
$28
0.5mm ID
2-pk.
21016
$28
Replacement ferrules for connecting transfer line to EZNo-Vent
: 0.4mm ID
2-pk.
21043
$25
Replacement 100µmdeactivated transfer line
3 ft.
21018
$20
Replacement EZNo-Vent
ColumnNut
5-pk.
21900
$30
Replacement EZNo-Vent
Plug
2-pk.
21915
$36
Open-EndWrenches (
1
/
4
" x
5
/
16
")
2-pk.
20110
$25
3.5 3.7 3.9 4.1 4.3 4.5 4.7 4.9 5.1 5.3 5.5
min.
2
1
3
4
5
6
7
3.5 3.7 3.9 4.1 4.3 4.5 4.7 4.9 5.1 5.3 5.5
min.
4
5
6
1
2
3
7
502.2 CalibrationMix#1 (gases) cat# 30042
1. dichlorodifluoromethane
2. 1,2-dichlorotetrafluoroethene (Freon
®
114)
3. chloromethane
4. vinyl chloride
5. bromomethane
6. chloroethane
7. trichlorofluoromethane
Column:
Rtx
®
-624 60m, 0.25mm ID, 1.4µm (cat# 10969)
Inj.:
purge& trap
GC
Agilent 6890
Inj. temp.:
300°C
Carrier gas:
helium, constant flow
Flow rate:
1.0mL/min.
Oven temp.:
60°C
Det:
Agilent 5973GC/MS
Transfer line temp.: 280°C
Scan range:
35-550 amu
Tune
BFB
Ionization:
EI
GC_EV00659a
GC_EV00659b
Figure2
Sharp, symmetricpeaks for gases show theEZNo-Vent™ connector doesnot adddeadvolumeandallows rapid column changes.
1st column, equilibrated system
Acquired76minutes after installing
2nd column, usingEZNo-Vent™
GC/MS
Interface
Transfer
Line
Ferrule
EZNo-Vent
Connector
Capillary
Ferrule
Capillary
Column
Transfer
Line
Figure1
A lasermachined
orifice, coupledwith the
100µm ID transfer line,
minimizes theamount of
oxygenentering theMS,
whicheliminates theneed
for purgegases.
Laserdrilled to
100µm ID
didyou
know
?
Restek offersmany innovative
tools and supplies for your
MS. Refer to our catalog or
website.
new
!
Each kit includes: EZNo-Vent
Connector, two 0.4mm ID ferrules for
capillary column, two 0.4mm ID ferrules
for transfer line, 100µm deactivated
transfer line (3 ft.), column plug, column
nut.
new
!
Nowavailable forVarian2000SeriesMSs
1...,62,63,64,65,66,67,68,69,70,71 73,74,75,76,77,78,79,80,81,82,...297
Powered by FlippingBook