Chromatography Columns 2013+ - page 7

USP:G27,G36,G41
DB-1,HP-1,AT-1,ZB-1,
007-1, Rtx-1, BP-1,
SPB-1,CP Sil 5CB
100%methyl polysiloxane
MEGA-1
Equivalent to
Tmax *
EPA - USP - Methods **
Applications
350°C
Stationary Phase
MEGA-5
5% phenyl,
95%methyl polysiloxane
MEGA-SE52
MEGA-SE54
MEGA-1701
MEGA-17
MEGA-WAX
DB-5,HP-5,AT-5,ZB-5,
007-5, Rtx-5, BP-5,
SPB-5,CP Sil 8CB
SE52
350°C
5% phenyl,
95%methyl polysiloxane
5% phenyl, 1% vinyl,
94%methyl polysiloxane
14% cyanopropylphenyl,
86%methyl polysiloxane
50% phenyl,
50%methyl polysiloxane
polyethylene glycol (PEG)
MEGA-1MS
MEGA-5MS
low bleeding 5% phenyl,
95%methyl polysiloxane
low bleeding
100%methyl polysiloxane
All trademarksmentioned in this document are registered.
*: the temperature rangemay change depending on the stationary phase film thickness.
**: download on our website amore complete guide to choose your GC column on the
basis of EPAmethods,USP requirements and/orASTMmethods (coming soon).
General purpose column.
Solvent impurities, PCBs,
simulated distillation, drugs, gases, natural gases,
essential oils, semivolatiles, pesticides, phenols, etc.
350°C
350°C
SE54
DB-1701,HP-1701,AT-1701,
ZB-1701, 007-1701, Rtx-1701,
BP-10, SPB-1701,CP Sil 19CB
280°C
EPA: 513, 515.2, 552.2, 607,
619, 622, 8091, 8121, etc.**
USP:G46
DB-17,DB-608,HP-17,AT-50,
ZB-50, 007-17, Rtx-17, BPX-50,
SPB-50,CP Sil 24CB
340°C
-
General purpose column.
Solvent impurities, PCBs,
hydrocarbons, essential oils, semivolatiles,
pesticides, etc
.
General purpose column.
Solvent impurities, PCBs,
hydrocarbons, essential oils, semivolatiles,
triglycerides, pesticides, poly-waxes, etc.
General purpose column.
Residual solvents , PCBs,
alcohols, oxygenates, pesticides, etc.
Ideal as confirmation column andGCxGC use.
EPA: 604, 608, 619, 8060, 8081
!
USP:G3,G17
250°C
350°C
350°C
DB-Wax,HP-Wax, InnoWax
AT-Wax,ZB-Wax, 007-CW,
Rtx-Wax, BP-20,CPWax 52CB
DB-1ms (UI),HP-1ms,
ZB-1ms, Rtx-1ms, BPX-1,
Equity-1,CP Sil 5CBms
DB-5ms (UI),HP-5ms,
AT-5ms,ZB-5ms, 007-5ms,
Rtx-5ms, BPX-5, Equity-5
General purpose column.
Solvent impurities, PCBs,
hydrocarbons, essential oils, semivolatiles,
allergens, pesticides, etc
.
General purpose column.
Phthalate esters,
herbicides, pharmaceuticals, etc.
Ideal as confirmation column andGCxGC use.
General purpose column.
FAMEs, flavor compounds,
essential oils, BTEX aromatics, solvents, alcohols, etc.
Tune yourWax column polarity! Ask us for more info.
General purpose column for GC-MS use.
SeeMEGA-1 phase.
General purpose column for GC-MS use.
SeeMEGA-5 phase.
EPA: 504.1, 505, 551, 606,
612, 8141A/B, etc.**
USP:G1,G2,G9,G38
EPA: 506, 611, 604, 607, 608,
8015, 8041, 8082, 8091, etc.**
USP:G27,G36,G41
EPA: 602, 603, 619,
8015CUSP 467 (OVIs), etc. **
USP:G14,G15,G16, etc.
EPA: 504.1, 505, 606, etc.**
!
USP:G1,G2,G9,G38
EPA: 513, 528, 552, 610, 613
1625, 8100, 8141A/B, etc.**
USP:G27,G36,G41
1,2,3,4,5,6 8,9,10,11,12,13,14,15,16,17,...
Powered by FlippingBook