Restek-TN Applications_344 - page 266

CLINICAL/FORENSICS
55
HPLC Accessories
MobilePhaseDegasser
Dissolved oxygen can cause flow rate instability and increased baseline
noise.Also, ithas aquenchingeffecton fluorescencedetectionand increas-
es the background of UV detectors. Dissolved gases can out-gas in the
HPLC system, formingbubbles incheckvalves, at connections,or indetec-
tor flow cells.
In-line vacuumdegassing ismore effective at removingdissolved gas from
mobile phases than sonication or helium sparging.Most in-line degassers withdraw gas across a gas-
permeable PTFE tubingmembrane, but the Degasys Ultimate Degasser uses tubing composed of an
amorphous fluoropolymer that is 200 to300 timesmoregaspermeable thanPTFE.This translates into
the ability to use shorter tubing for removing dissolved gas. This newmaterial also has better tubular
burst strength thanPTFE. To prevent cross contamination, each channel on this Degasys unit is indi-
vidually encasedwithin its own vacuum chamber.
Not recommended for usewith fluorinatedmobile phases, includingmobile phases containingTFA.
Description
qty.
cat.#
price
110VMobile PhaseDegasser (4 Channel, 7mL/min./channel)
ea.
25189
$2645
220VMobile PhaseDegasser (4 Channel, 7mL/min./channel)
ea.
25194
$2645
Mobile Phase: water:methanol
50:50
Flow:
1.0mL/min.
Det.:
UV@ 210nm
DegasysUltimate
Degasserprovides
highlystable
baselines
LC_0196
Ultimate
Degasser
Off
Ultimate
Degasser
On
SolventDebubbler
Bubbles in anHPLC system can cause check valvemalfunctions andpump cavitation, seriously affect-
ing pump performance. The debubbler removes bubbles from the fluid stream before it enters the
pump.Thegas/liquid interface is easilyvisible through the translucentwall of thedevice.Loosening the
airtight cap releases the trappedgas.Thedebubbler is fittedwithabracketanduniversal connecting tips.
Description
qty.
cat.#
price
Solvent Debubbler with Bracket
ea.
25014
$57
Sidewinder™ColumnHeater
• Easy to set up!
• Operation range: 5°C above ambient to85°C,±1°C.
• Lightweight, compact design fits in small spaces.
• Columnholder canbe placed in anyorientation.
Thisuniquedesigncompletelyencloses anyHPLCanalytical columnup to25cm in length.Two lengths
of heater jackets are available: the short columnholder accommodates columns up to 10cm in length,
while the long columnholder holds columns up to25cm in length.The controlmoduleprovides opti-
mumheatingperformance,accuracy towithin1°C,and stability towithin0.1°C.ThenewSidewinder™
controller has fast 10Hz sampling for improved responsiveness. Power requirements: 24V control unit
formaximum stability; RS232 control allows external programming.
Description
qty.
cat.#
price
Temperature Control Module and Long ColumnHolder, 25cmHolder
ea.
26516
$1295
Temperature Control Module and Short ColumnHolder, 10cmHolder
ea.
26517
$1295
Sidewinder™Heater/CoolerTemperatureControlModule
• Operation range: 5 - 55°C,±0.2°C.
• Ability toprogrammultiple temperature points.
• Accommodates columns up to30cm in length and7.8mm ID.
• Compact design.
The Sidewinder™ heater/cooler unit has a doubly insulated cover tomaintain the programmed tem-
perature to within 0.2°C. The 24V control unit provides maximum stability and rapid equilibration
times; RS232 control allows external programming.
All Sidewinder™ temperature
control products carry the
value recognized CEmark.
Each unit meets the demand-
ing electromagnetic emission
standards of the new
EuropeanUnionDirectives,
United States standards, and
Canadian standards.
Description
qty.
cat.#
price
Sidewinder™Heater/CoolerTemperature Control Module
ea.
26518
$2195
Specifications:
Residual Oxygen¹
Pressure Loss¹
Internal Volume
Wetted Parts
Max FlowRate
0.9ppm
0.24psi
500µL
Teflon
®
AF
7mL/min./channel
PTFE
ETFE
PPS
¹ At a flow rate of 1mL/min.